Programik do kontroli i przeglądu sprzętowego raida Dell dla Linuksa:

perccli_7.1623.00_a11_linux.tar.gz

Sprawdzony na Fedorze 35, 36, 37, 38, 39 oraz Red Hacie 8 ale na innych dystrybucjach też pewnie działa.

Przykłady użycia:

# /opt/MegaRAID/perccli/perccli64 show
CLI Version = 007.1623.0000.0000 May 17, 2021
Operating system = Linux 5.16.16-200.fc35.x86_64
Status Code = 0
Status = Success
Description = None

Number of Controllers = 1
Host Name = aegis.ping.local
Operating System  = Linux 5.16.16-200.fc35.x86_64

System Overview :
===============

-----------------------------------------------------------------------------
Ctl Model             Ports PDs DGs DNOpt VDs VNOpt BBU sPR DS EHS ASOs Hlth 
-----------------------------------------------------------------------------
  0 PERC6/iIntegrated     8   4   1     0   1     0 N/A On  2  N      0 Opt  
-----------------------------------------------------------------------------


# /opt/MegaRAID/perccli/perccli64 /c0 /eall /sall show all
CLI Version = 007.1623.0000.0000 May 17, 2021
Operating system = Linux 5.16.16-200.fc35.x86_64
Controller = 0
Status = Success
Description = Show Drive Information Succeeded.


Drive /c0/e32/s0 :
================

------------------------------------------------------------------------------
EID:Slt DID State DG       Size Intf Med SED PI SeSz Model            Sp Type 
------------------------------------------------------------------------------
32:0      0 Onln   0 418.625 GB SAS  HDD N   N  512B X411_HVIPC420A15 U  -    
------------------------------------------------------------------------------

EID=Enclosure Device ID|Slt=Slot No|DID=Device ID|DG=DriveGroup
DHS=Dedicated Hot Spare|UGood=Unconfigured Good|GHS=Global Hotspare
UBad=Unconfigured Bad|Sntze=Sanitize|Onln=Online|Offln=Offline|Intf=Interface
Med=Media Type|SED=Self Encryptive Drive|PI=Protection Info
SeSz=Sector Size|Sp=Spun|U=Up|D=Down|T=Transition|F=Foreign
UGUnsp=UGood Unsupported|UGShld=UGood shielded|HSPShld=Hotspare shielded
CFShld=Configured shielded|Cpybck=CopyBack|CBShld=Copyback Shielded
UBUnsp=UBad Unsupported|Rbld=Rebuild


Drive /c0/e32/s0 - Detailed Information :
=======================================

Drive /c0/e32/s0 State :
======================
Shield Counter = 0
Media Error Count = 0
Other Error Count = 0
Drive Temperature =  36C (96.80 F)
Predictive Failure Count = 0
S.M.A.R.T alert flagged by drive = No


Drive /c0/e32/s0 Device attributes :
==================================
SN = JYVDUT0J        
Manufacturer Id = NETAPP  
Model Number = X411_HVIPC420A15
NAND Vendor = NA
WWN = NA
Raw size = 419.186 GB [0x3465f870 Sectors]
Coerced size = 418.625 GB [0x34540000 Sectors]
Non Coerced size = 418.686 GB [0x3455f870 Sectors]
Device Speed = Unknown
Link Speed = Unknown
Write Cache = N/A
Logical Sector Size = 512B
Physical Sector Size = 512B
Connector Name = 

[...]