Programik do kontroli i przeglądu sprzętowego raida Dell dla Linuksa:
perccli_7.1623.00_a11_linux.tar.gz
Sprawdzony na Fedorze 35, 36, 37, 38, 39 oraz Red Hacie 8 ale na innych dystrybucjach też pewnie działa.
Przykłady użycia:
# /opt/MegaRAID/perccli/perccli64 show CLI Version = 007.1623.0000.0000 May 17, 2021 Operating system = Linux 5.16.16-200.fc35.x86_64 Status Code = 0 Status = Success Description = None Number of Controllers = 1 Host Name = aegis.ping.local Operating System = Linux 5.16.16-200.fc35.x86_64 System Overview : =============== ----------------------------------------------------------------------------- Ctl Model Ports PDs DGs DNOpt VDs VNOpt BBU sPR DS EHS ASOs Hlth ----------------------------------------------------------------------------- 0 PERC6/iIntegrated 8 4 1 0 1 0 N/A On 2 N 0 Opt ----------------------------------------------------------------------------- # /opt/MegaRAID/perccli/perccli64 /c0 /eall /sall show all CLI Version = 007.1623.0000.0000 May 17, 2021 Operating system = Linux 5.16.16-200.fc35.x86_64 Controller = 0 Status = Success Description = Show Drive Information Succeeded. Drive /c0/e32/s0 : ================ ------------------------------------------------------------------------------ EID:Slt DID State DG Size Intf Med SED PI SeSz Model Sp Type ------------------------------------------------------------------------------ 32:0 0 Onln 0 418.625 GB SAS HDD N N 512B X411_HVIPC420A15 U - ------------------------------------------------------------------------------ EID=Enclosure Device ID|Slt=Slot No|DID=Device ID|DG=DriveGroup DHS=Dedicated Hot Spare|UGood=Unconfigured Good|GHS=Global Hotspare UBad=Unconfigured Bad|Sntze=Sanitize|Onln=Online|Offln=Offline|Intf=Interface Med=Media Type|SED=Self Encryptive Drive|PI=Protection Info SeSz=Sector Size|Sp=Spun|U=Up|D=Down|T=Transition|F=Foreign UGUnsp=UGood Unsupported|UGShld=UGood shielded|HSPShld=Hotspare shielded CFShld=Configured shielded|Cpybck=CopyBack|CBShld=Copyback Shielded UBUnsp=UBad Unsupported|Rbld=Rebuild Drive /c0/e32/s0 - Detailed Information : ======================================= Drive /c0/e32/s0 State : ====================== Shield Counter = 0 Media Error Count = 0 Other Error Count = 0 Drive Temperature = 36C (96.80 F) Predictive Failure Count = 0 S.M.A.R.T alert flagged by drive = No Drive /c0/e32/s0 Device attributes : ================================== SN = JYVDUT0J Manufacturer Id = NETAPP Model Number = X411_HVIPC420A15 NAND Vendor = NA WWN = NA Raw size = 419.186 GB [0x3465f870 Sectors] Coerced size = 418.625 GB [0x34540000 Sectors] Non Coerced size = 418.686 GB [0x3455f870 Sectors] Device Speed = Unknown Link Speed = Unknown Write Cache = N/A Logical Sector Size = 512B Physical Sector Size = 512B Connector Name = [...]